Technical parameters of a construction system Flexibuild

Home page -  Construction system -  Technical parameters of a construction system Flexibuild

LOWER STRUCTURE

NOT INCLUDED IN A STANDARD OFFER- MAY BE REALIZED on CUSTOMER´S REQUEST FOR AN ADDITIONAL CHARGE

  • Foundation strips from plain concrete C8/10, width 40cm, depth 90–120cm
  • Gravel subbase (or crashed spoil) under the foundation slab, 10cm thick, loadbearing capacity 5kPa
  • Foundation slab 15cm thick with reinforcing cage 100/100/6.3
  • Damp-proofing
  • Radon protection- according to the radon degree of a land

OVERHEAD CONSTRUCTION

Exterior

  • tight coat th. 4 mm
  • spackle with glass-fibre reinforcement th. 4 mm
  • Flexibuild insulation panel IP6 (1+5cm)
  • Flexibuild board th. 15 mm
  • wooden frame construction with thermal insulation EPS100 Stabil
  • Flexibuild board th. 15 mm
  • vapour barier th. 0.2mm
  • closed air gap th. 60mm
  • Flexibuild board th. 15 mm
  • spackle with glass-fibre reinforcement th. 4 mm
  • tight coat th. 4 mm

Interior

  • partitions 0,132 m thick
  • tight coat th. 2 mm
  • spackle with glass-fibre reinforcement th. 4 mm
  • Flexibuild board th. 10 mm
  • wooden frame construction 100mm thick with thermal insulation EPS 100 Stabil
  • Flexibuild board 10 mm
  • tight coat th. 2 mm

ROOF STRUCTURE AND COVERING

  • loadbearing construction of a roof according to the design project
  • concrete roof tile

GUTTERS AND DOWNPINES

  • zinc coating
  • outlet 10 cm under the edge of a foundation slab

UNDER FLOORING

One-storey building

Floor structure – ground floor:

  • Thermal insulation and sound protection EPS 100 Stabil th. 5 cm
  • Insulating Flexibuild panel 1+5 (Flexibuild board 1cm + 5cm EPS 100 Stabil)
  • Flexibuild board 1,5 cm (layed down on cross bond, screwed together per 30 cm)

Ceiling structure – ground floor:

  • According to the design project
  • Flexibuild board 15 mm thick as a suspended ceiling
  • Thermal insulation and sound protection according to the design project and eurocodes

Two-storey building

Floor structure – ground floor:

  • Thermal insulation and sound protection EPS 100 Stabil th. 5 cm
  • Insulating Flexibuild panel 1+5 (Flexibuild board 1cm + 5cm EPS 100 Stabil)
  • Flexibuild board 1,5 cm (layed down on cross bond, screwed together per 30 cm)

Floor structure – second floor (ceiling of a ground floor)

  • Loadbearing beams (amount and size according to the static design)
  • Flexibuild board 15 mm thick as a suspended ceiling
  • Thermal insulation and sound protection according to the design project and eurocodes
  • Bearing layer 2×1,5 cm Flexibuild board (layed down on cross bond, screwed together per 30 cm)

Ceiling structure – second floor:

  • According to the design project
  • Flexibuild board 15 mm thick as a suspended ceiling
  • Thermal insulation and sound protection according to the design project and eurocodes

WINDOWS AND BALCONY DOOR

  • standard window size – 1200×1400 mm
  • plastique material, 5-chamber profile of a window frame and window wing, white color
  • window fittings with opened, hinged and micro-ventilating position
  • insulating double glass U = 1,1 W/m2K
  • balcony door of a standard height 2100 mm

WINDOW SILLS

  • outer window sills: anticorrosive aluminium profile, color white or brown
  • inner window sill: laminated shredded wood, arbitrary decorating

ENTRANCE DOOR

  • plastique material, white color